Refrigeration system for industrial ozone generator 200G

CHILLER RE500 designed for an ozone generator producing up to 200 g/O3/h

 

 

You would like to set up a solution with an ozone generator for water or air treatment. Contact us.

! Our range of ozonated water generators and water treatment systems is fitted as standard with an activated alumina bi-column oxygen concentrator to remove nitrogen from the air and not produce nitrogen oxides, for the safety of users and the environment. The oxygen produced and used is 95% pure !

CHILLER model RE200 for ozone generator

 

Industrial refrigeration system for ozone generators up to 200 g O3/h. With 3 PH, 380-415 V, 50 Hz and 3 kW cooling capacity.

Designed to maintain the appropriate and necessary temperature for your ozone generator up to 200 g/O3/h.

 

Technical specifications

 

  • Temperature control: accuracy of 1 ºC.
  • Cooling capacity: 3 kW.
  • Maximum power consumption: 8.4 kW.
  • Recirculation water flow rate 9 m3/h.
  • Maximum recirculation pump pressure 3.5 bar.
  • Length x Width x Height: 1600 x 720 x 1650 mm.
  • Weight: 350 kg.
  • Hose connection: 1 1/2". DN40
  • Tank volume: 200L.
  • LCD screen.
  • CE marking.

 

Working and environmental requirements

 

  • Maximum ambient temperature 5 to 35°C.
  • Do not block the vents.
  • Ventilate the room during operation.